MASK Control Systems - Bespoke Industrial Automation & Control Systems UK
ATEX Zone 1 & Zone 2 Process ControlDSEAR 2002 & BS EN 60079

Paints, Resins & Industrial Coatings Automation: ATEX Zone 1 Batching & Hazardous Process Control

Turnkey process automation, explosion-proof control panels, and precision solvent batching for UK manufacturers of industrial paints, synthetic resins, specialized coatings, and solvent-based printing inks. Engineered for strict DSEAR 2002 compliance, automated pigging pipeline cleanouts, and zero VOC release.

Sector: Chemical & Hazardous Coatings
16 min read
Ex d, Ex p, Ex i & SIL 2 Certified
Paints, resins, coatings and industrial printing inks automated ATEX manufacturing facility
Figure 1: High-integrity ATEX Zone 1 batch mixing facility featuring 316L stainless vessels, explosion-proof agitators, automated solvent manifold piping, and wall-mounted Ex d/Ex p control enclosures.

Executive Overview: The Automation Imperative in Coatings & Resins

Manufacturing industrial coatings, architectural paints, synthetic alkyd/epoxy resins, and high-speed packaging inks requires handling large volumes of volatile flammable solvents, including toluene, xylene, methyl ethyl ketone (MEK), and acetone. Under the UK Dangerous Substances and Explosive Atmospheres Regulations (DSEAR 2002), plant operators face rigorous statutory mandates to eliminate ignition sources, prevent vapor accumulation, and ensure verifiable static bonding.

MASK Control Systems Ltd designs, builds, and commissions turnkey ATEX-certified electrical control panels and SCADA architectures specifically for hazardous processing environments. By combining pressurized Ex p enclosures, galvanic intrinsic safety barriers, high-precision Coriolis flow metering, automated pigging cleanout, and ISA-88 recipe batching, we help UK coatings manufacturers eliminate human weighing errors, slash batch cycle times by 35%, and maintain unquestioned regulatory compliance.

6 Core Automation Engineering Pillars for Coatings Plants

1

ATEX Zone 1 & Zone 2 Enclosure Engineering (BS EN 60079)

Installing automation hardware inside classified flammable atmospheres requires distinct protection concepts. MASK Control Systems designs hybrid multi-protection control suites integrating:

Ex d (Flameproof)Heavy cast aluminum or cast iron housing contactors, circuit breakers, and high-energy switchgear without propagating internal sparks.
Ex p (Pressurized Purge)Overpressured stainless cabinets housing standard PLCs and HMIs with continuous clean air/nitrogen purge and automatic low-pressure disconnects.
Ex i (Intrinsic Safety)Galvanic isolators and zener barriers limiting electrical and thermal energy entering Zone 0/1 vessels via sensors and solenoids.
2

High-Shear Disperser & Explosion-Proof Agitator Motor Control

High-speed cowles dispersers and heavy anchor scrapers generate massive frictional heat during pigment grinding. We deploy Variable Frequency Drives (VFDs) paired with certified Ex d IIB+H2 T4 explosion-proof motors equipped with PTC thermistor monitoring. The PLC automatically modulates impeller RPM based on instantaneous motor torque and product temperature, preventing paint batch boiling and thermal degradation.

3

Precision Solvent Dosing, Mass Metering & Pigging Pipeline Systems

Eliminate dangerous manual drum decanting. Our automated dosing skids incorporate intrinsically safe Coriolis mass flowmeters providing sub-0.1% dosing precision directly from bulk solvent tank farms into reaction kettles. Between color batches, our automated pipeline pigging system uses compressed nitrogen to drive silicone pigs through transfer lines, recovering 99.5% of product residue and reducing solvent wash volumes by over 80%.

4

DSEAR Static Bonding Interlocks & Nitrogen Blanketing

Static discharge is the leading cause of solvent fires in paint factories. Our control panels integrate certified continuous ground monitoring clamps (e.g. Newson Gale) with hardwired SIL 2 permissive interlocks. Solvent inlet valves cannot actuate unless vessel grounding resistance is certified below 10 ohms and head-space nitrogen blanketing pressure is fully established.

5

ISA-88 Batch Recipe Automation & Color Tint Repeatability

Implemented via Siemens Simatic Batch or Rockwell FactoryTalk Batch, our systems organize production into modular ISA-88 phases (solvent pre-charge, pigment addition, high-speed dispersion, let-down resin blending, tinting, and filtration). Every addition is logged with barcode validation and timestamped electronic batch records (EBR).

6

VOC Vapor Extraction & Thermal Oxidizer (RTO) Interlocks

To comply with Environment Agency emissions permits, extraction ventilation must remain synchronized with processing equipment. Our automation monitors LEV duct air velocity, packed-bed chemical scrubber recirculating pump flow, and burner safety interlocks on Regenerative Thermal Oxidizers (RTOs), preventing unburned VOC bypass.

ATEX & Hazardous Process Control Specification Matrix

Engineering standards and component specifications deployed across MASK industrial coatings control panels:

Engineering ParameterIndustrial Standard / RatingMASK Engineering Execution
Hazardous Area ClassificationATEX Zone 1 / Zone 2 (Gases, Vapors, Mists)Gas Groups IIA, IIB, and IIB+H2; Temp Class T3/T4
Panel Enclosure ConceptsEx d (Flameproof) & Ex p (Pressurized Purge)Continuous purge controllers with automatic shutdown on pressure failure
Instrumentation LoopsEx ia / Ex ib (Intrinsic Safety)Galvanic isolators for 4-20mA pressure, RTD, and level transmitters
Static Grounding ProtectionDSEAR 2002 & CLC/TR 60079-32-1Interlocked ground clamps with resistance verification < 10 ohms
Functional Safety ArchitectureBS EN ISO 13849-1 / IEC 61508Failsafe Safety PLCs achieving Performance Level d/e (SIL 2/3)
Batch ArchitectureANSI/ISA-88.01 (S88 Standard)Modular recipe phases with 21 CFR Part 11 compliant audit logging

Table 1: Technical specification matrix for hazardous coatings process control panels built by MASK Control Systems Ltd.

Frequently Asked Questions: Coatings & Resin Automation

What ATEX protection methods are used for control panels in paint manufacturing?
In ATEX Zone 1 and Zone 2 solvent environments, MASK Control Systems utilizes Ex d flameproof cast enclosures for heavy power components, Ex p positive-pressure purged cabinets with continuous inert gas/air purging, and segregated Ex i intrinsic safety barriers for digital and analog instrumentation in vapor zones.
How does an Ex p pressurized cabinet protect automation electronics in solvent areas?
An Ex p enclosure maintains a continuous positive internal pressure relative to the surrounding room using clean dry air or nitrogen. Before power is energized, an automated pre-purge cycle flushes any residual solvent vapors. If internal pressure drops below statutory thresholds, power is automatically and safely disconnected.
Can MASK automation systems manage automated pigging pipeline cleanouts?
Yes. Our PLC systems automate complete sanitary and chemical pigging sequences: launching foam or magnetic pigs via propellant air/nitrogen, tracking pig velocity via magnetic proximity sensors, verifying full pipe cleanout, and safely recovering solvent residues without manual intervention.
What safety interlocks are legally mandatory under DSEAR 2002 for solvent addition?
Under the Dangerous Substances and Explosive Atmospheres Regulations (DSEAR 2002), mandatory controls include static grounding verification interlocks, vessel nitrogen blanketing confirmation, mixer speed interlocks preventing agitation before minimum liquid submersion, and automated solvent shut-off valves linked to LEL gas detectors.
How do high-shear disperser VFDs prevent motor overheating in hazardous zones?
We integrate certified Ex d / Ex eb variable speed motors equipped with dual embedded PTC thermistors and force-ventilated auxiliary explosion-proof cooling fans. Our PLC logic actively tracks drive thermal curves and adjusts agitation RPM dynamically as viscosity rises during pigment dispersion.
Does MASK Control Systems supply full DSEAR and ATEX compliance documentation?
Yes. Every project includes comprehensive EPLAN electrical schematics, intrinsic safety loop calculation sheets, hazardous area equipment certificates, ignition risk assessments, and Operation & Maintenance (O&M) manuals satisfying UK HSE inspectorate standards.
Hazardous Area Engineering Specialists

Modernize Your Coatings & Resins Facility with MASK Control Systems

Whether retrofitting an existing solvent mixing plant or engineering a turnkey ATEX Zone 1 resin reaction skid, our certified EC&I engineers provide end-to-end design, panel manufacturing, and UK-wide commissioning.

DSEAR 2002 CertifiedCompEx Qualified Engineers100% Unlocked Code Handover
WhatsApp