Municipal Clean Water Treatment Automation: Rapid Gravity Filtration, Chemical Dosing Skids & WIMES 3.01 Compliance
Engineered for UK water utility frameworks, municipal water authorities, and tier-1 EC&I contractors. MASK Control Systems Ltd delivers bespoke WIMES 3.01 Form 4 Type 6/7 Motor Control Centres (MCCs), automated rapid gravity filter backwash sequencing, precision chemical dosing skids, and cyber-secure WITS-DNP3 telemetry outstations.

Custom WIMES Form 4 MCCs engineered in Cullompton, Devon.
Engineering Clean Potable Water for UK Utility Frameworks
Municipal potable water treatment is a vital national infrastructure asset that operates under unrelenting regulatory oversight from the Drinking Water Inspectorate (DWI) and the Environment Agency. A momentary failure in coagulation chemical dosing, a ruptured filter bed, or an erratic chlorine residual can contaminate municipal mains supply, triggering boil-water notices and multimillion-pound statutory fines.
Headquartered in Cullompton, Devon, MASK Control Systems Ltd delivers robust, fail-safe automation across the potable water treatment cycle. We engineer WIMES 3.01 compliant Motor Control Centres, rapid gravity filter backwash sequencers, chemical dosing skids, high-lift distribution pump stations, and cyber-secure WITS-DNP3 telemetry systems trusted by UK water utility frameworks.
Specialized Water Treatment Process Automation Disciplines
From raw river abstraction through to service reservoir distribution, our engineering team deploys deterministic, low-maintenance control architectures:
Rapid Gravity Filter (RGF) Backwash Loops
Automated sequencing based on differential head loss and turbidity timers. Manages raw inlet penstocks, dirty washwater valves, air scour blowers, backwash pumps, and filter-to-waste ripening loops until turbidity falls below 0.1 NTU.
Coagulation & Chemical Dosing Skids
Flow-proportional and streaming current detector (SCD) closed-loop dosing for coagulants (ferric/alum sulphate) and polymer coagulant aids. Features automated duty/standby peristaltic and diaphragm pump switchover with leak detection.
Chlorination & Disinfection Control
Triple-validated free chlorine and total chlorine amperometric analyzers governing sodium hypochlorite dosing and gaseous chlorination. Integrates contact tank residence time calculations and automated fail-closed isolation valves.
WIMES 3.01 Form 4 Type 6/7 MCCs
Motor Control Centres built to British water specifications. Features fully segregated withdrawable starter buckets, isolated busbar chambers, 50kA 1-second fault withstand ratings, and integrated VFD motor protection relays.
High-Lift Distribution Pump Stations
Multi-megawatt clean water distribution pump staging. Automates variable-speed drive sequencing based on district metered area (DMA) pressure, surge vessel pneumatic pressure regulation, and acoustic pipe burst detection algorithms.
WITS-DNP3 Unmanned Outstations
Water Industry Telemetry Standards compliant RTU outstations. Features dual-SIM 4G/5G cellular and private UHF radio communications reporting service reservoir levels, flow totals, and water quality alerts to regional master SCADA.
WIMES 3.01, DWI Regulation 31 & MCERTS Compliance
Engineering control systems for potable water works demands strict compliance with British water utility guidelines. Inadequate busbar segregation, non-approved sensor wetted materials, or uncalibrated flowmeters can void framework contracts and halt plant commissioning.
MASK Control Systems ensures complete legal and framework compliance across all installations:
- WIMES 3.01 Form 4 Type 6/7 Segregation: All motor starters, feeder compartments, and incoming circuit breakers are individually compartmentalised with dedicated integral glanding boxes.
- DWI Regulation 31 Certification: All flowmeters, pressure sensors, and analytical probes in contact with water possess valid certificates verifying zero toxicity or water leaching.
- NIS Regulations Cybersecurity: Telemetry systems and PLC hardware incorporate encrypted protocols, port lockdowns, and hardware firewalls conforming to UK Critical National Infrastructure (CNI) guidelines.
Clean Water Compliance Matrix
Mandatory low-voltage switchgear and controlgear assembly build rules for all UK water companies.
Strict statutory approval for all wetted chemicals, pipes, and sensors contacting drinking water.
Certified flow abstraction measurement ensuring legal compliance with water abstraction licenses.
Interoperable secure protocol standardizing telemetry outstations and master regional SCADA.
PLC Hardware, Hot-Standby Redundancy & Regional SCADA
We engineer scalable automation platforms tailored to the approved vendor asset standards of UK water utilities:
Rockwell ControlLogix
Hot-Standby RedundantDual-chassis 1756 ControlLogix redundant controllers with fiber optic sync modules. Delivers bumpless sub-millisecond CPU switchover for major potable water treatment works and pumping skids.
Siemens S7-1500R/H
High-AvailabilityRedundant S7-1500H controllers paired with ET 200SP PROFINET MRP ring topology. Standardized on South West Water and Severn Trent frameworks for critical filtration and dosing assets.
Geo SCADA & WITS RTUs
ClearSCADA OutstationsIntegration with Schneider Geo SCADA Expert (ClearSCADA) and WITS-DNP3 RTU outstations. Delivers automated data logging, alarm dial-outs, and historical trending for remote service reservoirs.
Frequently Asked Questions: Clean Water Automation
Key questions asked by UK water utility engineers, framework managers, and EC&I contractors:
What is WIMES 3.01 and why is it mandatory for UK water utility control panels?
How does automated rapid gravity filter (RGF) backwashing operate?
How do your chemical dosing control skids prevent chlorine over-dosing?
Which telemetry protocols are used to communicate with regional water company SCADA?
How do you ensure Drinking Water Inspectorate (DWI) Regulation 31 compliance?
Upgrade Your Water Treatment Works with WIMES 3.01 Compliance
Discuss your water treatment plant upgrade, WIMES Form 4 MCC manufacture, rapid gravity filter automation, or WITS-DNP3 telemetry with our senior EC&I engineers. We deliver bespoke electrical designs, proven PLC software, and seamless on-site commissioning across the UK.