MASK Control Systems - Bespoke Industrial Automation & Control Systems UK
Municipal Water TreatmentWIMES 3.01 & MCERTS Compliant

Municipal Clean Water Treatment Automation: Rapid Gravity Filtration, Chemical Dosing Skids & WIMES 3.01 Compliance

Engineered for UK water utility frameworks, municipal water authorities, and tier-1 EC&I contractors. MASK Control Systems Ltd delivers bespoke WIMES 3.01 Form 4 Type 6/7 Motor Control Centres (MCCs), automated rapid gravity filter backwash sequencing, precision chemical dosing skids, and cyber-secure WITS-DNP3 telemetry outstations.

Municipal Clean Water Treatment Automation and WIMES 3.01 Control Panels UK

Custom WIMES Form 4 MCCs engineered in Cullompton, Devon.

Form 4b Type 7
WIMES 3.01 Segregated Switchgear
< 0.1 NTU
Automated Filter Ripening Quality
DWI Reg 31
Potable Water Wetted Materials
WITS-DNP3
Water Industry Telemetry Outstation

Engineering Clean Potable Water for UK Utility Frameworks

Municipal potable water treatment is a vital national infrastructure asset that operates under unrelenting regulatory oversight from the Drinking Water Inspectorate (DWI) and the Environment Agency. A momentary failure in coagulation chemical dosing, a ruptured filter bed, or an erratic chlorine residual can contaminate municipal mains supply, triggering boil-water notices and multimillion-pound statutory fines.

Headquartered in Cullompton, Devon, MASK Control Systems Ltd delivers robust, fail-safe automation across the potable water treatment cycle. We engineer WIMES 3.01 compliant Motor Control Centres, rapid gravity filter backwash sequencers, chemical dosing skids, high-lift distribution pump stations, and cyber-secure WITS-DNP3 telemetry systems trusted by UK water utility frameworks.

Technical Capabilities

Specialized Water Treatment Process Automation Disciplines

From raw river abstraction through to service reservoir distribution, our engineering team deploys deterministic, low-maintenance control architectures:

Rapid Gravity Filter (RGF) Backwash Loops

Automated sequencing based on differential head loss and turbidity timers. Manages raw inlet penstocks, dirty washwater valves, air scour blowers, backwash pumps, and filter-to-waste ripening loops until turbidity falls below 0.1 NTU.

Sub-0.1 NTU Ripening & Air Scour Sequencing

Coagulation & Chemical Dosing Skids

Flow-proportional and streaming current detector (SCD) closed-loop dosing for coagulants (ferric/alum sulphate) and polymer coagulant aids. Features automated duty/standby peristaltic and diaphragm pump switchover with leak detection.

Streaming Current & Flow-Pacing Precision

Chlorination & Disinfection Control

Triple-validated free chlorine and total chlorine amperometric analyzers governing sodium hypochlorite dosing and gaseous chlorination. Integrates contact tank residence time calculations and automated fail-closed isolation valves.

Triple-Validated Residual & Fail-Closed Valves

WIMES 3.01 Form 4 Type 6/7 MCCs

Motor Control Centres built to British water specifications. Features fully segregated withdrawable starter buckets, isolated busbar chambers, 50kA 1-second fault withstand ratings, and integrated VFD motor protection relays.

Withdrawable Buckets & 50kA Withstand Ratings

High-Lift Distribution Pump Stations

Multi-megawatt clean water distribution pump staging. Automates variable-speed drive sequencing based on district metered area (DMA) pressure, surge vessel pneumatic pressure regulation, and acoustic pipe burst detection algorithms.

Surge Suppression & DMA Pressure Modulation

WITS-DNP3 Unmanned Outstations

Water Industry Telemetry Standards compliant RTU outstations. Features dual-SIM 4G/5G cellular and private UHF radio communications reporting service reservoir levels, flow totals, and water quality alerts to regional master SCADA.

WITS-DNP3 Protocols & Cyber-Secure Outstations
Statutory Specifications

WIMES 3.01, DWI Regulation 31 & MCERTS Compliance

Engineering control systems for potable water works demands strict compliance with British water utility guidelines. Inadequate busbar segregation, non-approved sensor wetted materials, or uncalibrated flowmeters can void framework contracts and halt plant commissioning.

MASK Control Systems ensures complete legal and framework compliance across all installations:

  • WIMES 3.01 Form 4 Type 6/7 Segregation: All motor starters, feeder compartments, and incoming circuit breakers are individually compartmentalised with dedicated integral glanding boxes.
  • DWI Regulation 31 Certification: All flowmeters, pressure sensors, and analytical probes in contact with water possess valid certificates verifying zero toxicity or water leaching.
  • NIS Regulations Cybersecurity: Telemetry systems and PLC hardware incorporate encrypted protocols, port lockdowns, and hardware firewalls conforming to UK Critical National Infrastructure (CNI) guidelines.

Clean Water Compliance Matrix

WIMES 3.01 Issue 7 SpecificationUK Water Standard

Mandatory low-voltage switchgear and controlgear assembly build rules for all UK water companies.

DWI Regulation 31 Potable WaterMaterial Approval

Strict statutory approval for all wetted chemicals, pipes, and sensors contacting drinking water.

Environment Agency MCERTSMetering Certified

Certified flow abstraction measurement ensuring legal compliance with water abstraction licenses.

WITS-DNP3 Telemetry StandardSCADA Protocol

Interoperable secure protocol standardizing telemetry outstations and master regional SCADA.

Control Architecture

PLC Hardware, Hot-Standby Redundancy & Regional SCADA

We engineer scalable automation platforms tailored to the approved vendor asset standards of UK water utilities:

Rockwell ControlLogix

Hot-Standby Redundant

Dual-chassis 1756 ControlLogix redundant controllers with fiber optic sync modules. Delivers bumpless sub-millisecond CPU switchover for major potable water treatment works and pumping skids.

Siemens S7-1500R/H

High-Availability

Redundant S7-1500H controllers paired with ET 200SP PROFINET MRP ring topology. Standardized on South West Water and Severn Trent frameworks for critical filtration and dosing assets.

Geo SCADA & WITS RTUs

ClearSCADA Outstations

Integration with Schneider Geo SCADA Expert (ClearSCADA) and WITS-DNP3 RTU outstations. Delivers automated data logging, alarm dial-outs, and historical trending for remote service reservoirs.

Technical Guidance

Frequently Asked Questions: Clean Water Automation

Key questions asked by UK water utility engineers, framework managers, and EC&I contractors:

What is WIMES 3.01 and why is it mandatory for UK water utility control panels?
WIMES 3.01 (Water Industry Mechanical and Electrical Specification) is the definitive technical standard adopted by all UK water and sewerage companies for low-voltage switchgear and controlgear assemblies. It mandates strict physical compartmentalisation (typically Form 4 Type 6 or Form 4 Type 7), segregation of auxiliary wiring, fault level withstand ratings up to 50kA for 1 or 3 seconds, withdrawable functional starter units, and IP54 minimum ingress protection to guarantee operator safety during live maintenance.
How does automated rapid gravity filter (RGF) backwashing operate?
Our RGF automation continuously monitors filter bed head loss, turbidity levels, and runtime hours. When backwash triggers occur, the PLC executes a deterministic sequence: closing the raw water inlet penstock, opening the dirty washwater drainage valve, activating air scour blowers to dislodge entrained solids, and staging variable-speed backwash pumps. The system then executes a filter-to-waste ripening cycle until optical turbidity falls below 0.1 NTU before reconnecting the cell to the potable supply header.
How do your chemical dosing control skids prevent chlorine over-dosing?
Potable water disinfection requires fail-safe dosing controls. We deploy dual-redundant or triple-validated amperometric chlorine analyzers measuring free and total chlorine alongside high-accuracy electromagnetic flowmeters. The PLC calculates continuous chemical flow-pacing PID loops. If chlorine levels exceed upper critical limits or if sample water flow fails, the controller automatically trips the duty dosing pump, switches to standby, and isolates the chemical injection point with automated fail-closed actuated ball valves.
Which telemetry protocols are used to communicate with regional water company SCADA?
We integrate telemetry outstations conforming to WITS-DNP3 (Water Industry Telemetry Standards) and IEC 60870-5-104 over dual-redundant 4G/5G cellular and private radio networks. This ensures seamless bidirectional communication with regional utility SCADA masters (such as Schneider Geo SCADA Expert / ClearSCADA or Wonderware), enabling remote monitoring of service reservoirs, pump stations, and alarm dial-outs.
How do you ensure Drinking Water Inspectorate (DWI) Regulation 31 compliance?
Under Regulation 31 of the Water Supply (Water Quality) Regulations, any equipment or material in contact with treated drinking water must be strictly approved to prevent toxic chemical leaching or microbial growth. We ensure all wetted sensor housings, electromagnetic flowmeter linings (e.g. hard rubber / PTFE), and sample tubing possess current DWI approval certificates and WRAS certification.
Municipal Water Utility Engineering

Upgrade Your Water Treatment Works with WIMES 3.01 Compliance

Discuss your water treatment plant upgrade, WIMES Form 4 MCC manufacture, rapid gravity filter automation, or WITS-DNP3 telemetry with our senior EC&I engineers. We deliver bespoke electrical designs, proven PLC software, and seamless on-site commissioning across the UK.

WhatsApp