MASK Control Systems - Bespoke Industrial Automation & Control Systems UK
Brewery & Distillery EngineeringDSEAR & ATEX Zone 2 Compliant

Craft Brewing & Distilling Automation: Brewhouse Control Panels, ATEX Milling & Fermentation Systems

Engineered for UK craft breweries, whisky distilleries, and artisan gin producers. MASK Control Systems Ltd delivers custom brewhouse control panels, ATEX-compliant ethanol vapor safety, multi-zone glycol cellar refrigeration, and automated batch recipe management that guarantee repeatable product quality and energy efficiency.

Craft Brewhouse and Distillery Automation Control Panel Systems UK

Turnkey brewhouse and cellar automation engineered in Cullompton, Devon.

ATEX 1/2
Ethanol Vapor Hazardous Area Safety
±0.2°C
Multi-Zone Cellar Glycol Precision
ISA-88
Automated Batch Recipe Architecture
HMRC Duty
Automated Batch Volume Audit Logs

Balancing Brewing Craft with Rigorous Control Engineering

Craft brewing and artisan spirit distillation are rooted in artisanal recipes, but scaling production profitably requires uncompromising repeatability. Inconsistent mash conversion temperatures degrade fermentability; erratic boil vigor wastes expensive steam; and runaway fermentation temperatures ruin delicate ester profiles. Furthermore, ethanol vapors in distilleries and combustible grain dust in malt mills introduce severe regulatory obligations under DSEAR.

MASK Control Systems Ltd delivers turnkey electrical design, ATEX hazardous area integration, and PLC/SCADA programming specifically tailored for UK beverage producers. From multi-vessel brewhouses (HLT, Mash Tun, Lauter Tun, Kettle, Whirlpool) to spirit pot stills and automated cellar tank farms, we engineer solutions that empower head brewers and distillers with complete process control.

Process Automation Scope

Turnkey Control for Brewhouse, Distilling & Cellar Operations

From malt intake and grain hydration through to spirit distillation and kegging, our engineering team implements deterministic automation designed around your specific craft recipes:

Malt Intake & ATEX Zone 21/22 Grinding

Dry grain handling creates combustible dust hazards. We engineer ATEX-rated malt augers, de-stoner interlocks, and two-roller/four-roller mill speed controls with integrated magnetic metal traps, spark detection, and explosion relief monitoring compliant with DSEAR.

Combustible Dust DSEAR Compliance

Mash & Lauter Tun Automation

Automated strike water temperature blending via modulating steam valves and hygienic flowmeters. Features variable-speed rakes height and rotation VFDs, differential pressure differential vorlauf recirculation monitoring, and automated sparge water sequencing.

Extract Yield & Wort Clarity Optimization

Wort Kettle & Whirlpool Management

Dynamic steam jacket modulating pressure control ensuring vigorous rolling boil while eliminating boil-overs via optical foam sensors. Automates multi-stage hop addition dosers, whirlpool spin timing, trub settling rests, and counterflow heat exchanger cooling.

Energy Recovery & DMS Evaporation Control

Cellar Glycol & Fermentation Control

Individual dual-zone glycol solenoid valve regulation for 10 to 50+ conical Unitanks. Supports custom fermentation curves, programmed diacetyl rest temperature steps, cold crash cooling schedules, and real-time cellar manifold pressure telemetry.

Multi-Zone Jacket Precision ±0.2°C

Distillery Pot Still & Column Automation

Precision steam boiler modulation for wash stills and spirit stills. Automates dephlegmator reflux temperature, condenser cooling water flow, and automated pneumatic divert cut switching between foreshots, hearts, and feints based on vapor temperature and alcohol proof.

Automated Spirit Cut Switching & Proof Tracking

Automated Brewhouse CIP & Sanitisation

Dedicated skid control for 2-tank and 3-tank CIP sets (hot caustic, acid neutraliser, cold sanitiser). Features automatic recovery rinse logic, conductivity verification, and pump frequency regulation to ensure turbulent pipe cleaning velocities.

Chemical Recovery & Hygiene Validation
Hazardous Area Safety

DSEAR & ATEX Zone 1/2 Certified Engineering for UK Distilleries

Distilling ethanol creates flammable vapor concentrations that can easily ignite from electrical sparks, hot surfaces, or electrostatic discharges. The Health and Safety Executive (HSE) enforces strict compliance under the Dangerous Substances and Explosive Atmospheres Regulations (DSEAR 2002).

MASK Control Systems ensures complete legal compliance through certified engineering practices:

  • Intrinsically Safe Circuits (Ex i): Field sensors located on still heads, condensers, and spirit safes are isolated using Pepperl+Fuchs galvanic isolator barriers, limiting electrical energy below ignition levels.
  • Purged & Pressurised Enclosures (Ex p): Where HMIs or controls must reside in spirit room areas, we design positive-pressure inert air purge systems with automatic power cutoffs upon pressure loss.
  • Earthing & Static Bonding Audits: Comprehensive bonding of stainless pipework, spirit pumps, and transfer hoses to eliminate static accumulation during high-volume spirit transfers.

Brewery & Distillery Compliance Matrix

DSEAR 2002 Statutory RegulationUK Legal Standard

Mandatory hazardous area classification and risk mitigation for flammable spirit storage and grain milling.

BS EN 60079 Explosive AtmospheresEx Equipment Build

Certified Ex d, Ex e, and Ex i electrical equipment selection for gas (Zone 1/2) and dust (Zone 21/22).

ISA-88 Batch Recipe StandardModular Software

Standardised batch control architecture separating equipment phases from specific product recipes.

HMRC Notice 197 / Spirits DutyAudit Traceability

Automated digital logging of production volumes, temperature compensation, and spirit transfer records.

Control Architecture

PLC Platforms, Remote SCADA & Cloud Recipe Control

We engineer scalable automation platforms matching your brewery or distillery budget and expansion goals:

Siemens TIA Portal

S7-1500 & ET 200SP

Standard platform for high-throughput commercial breweries. Features modular SCL function blocks for PID steam valves, PROFINET remote I/O on brewhouse skids, and seamless WinCC Unified touchscreen HMI graphics.

Rockwell Automation

CompactLogix 5380

Engineered using Studio 5000 Logix Designer. Ideal for modular brewhouses requiring expandable POINT I/O, EtherNet/IP valve manifolds, and intuitive Ladder logic diagnostics for internal maintenance teams.

Ignition SCADA & Cloud

Web & Mobile Access

Real-time web-based SCADA dashboards accessible from any tablet or phone. View cellar tank temperatures, receive automated fermentation alerts, log energy usage per barrel, and export HMRC audit reports.

Technical Guidance

Frequently Asked Questions: Brewing & Distilling

Expert answers regarding DSEAR compliance, automated mashing, and spirit cut regulation:

How does MASK Control Systems ensure DSEAR and ATEX compliance in distilleries?
Ethanol vapour emitted during distilling constitutes an explosive atmosphere classified under DSEAR as ATEX Zone 1 or Zone 2. We design intrinsically safe galvanic isolation barriers (Ex i) for all tank instrumentation, utilize flameproof Ex d or increased safety Ex e junction boxes in hazardous zones, and place main non-Ex control panels outside the classified boundary. In addition, grain milling areas are engineered to mitigate combustible dust ignition under ATEX Zone 21/22 guidelines.
Can your brewhouse automation system execute multi-step infusion mashing automatically?
Yes. Our PLC automation systems execute fully automated multi-step temperature infusion profiles. The controller manages strike water blending valves, rakes speed and elevation VFDs, underlet water additions, and recirculation vorlauf cycles. Transitioning between beta-amylase holds, alpha-amylase conversion rests, and mash-out temperatures occurs with sub-degree accuracy, guaranteeing consistent extract efficiency and fermentability batch after batch.
How is automated cut switching handled in commercial spirit distillation?
In batch pot stills and continuous columns, automated spirit cut sequencing between foreshots (heads), hearts (potable product), and feints (tails) is achieved via high-precision vapor temperature transmitters, inline Coriolis mass flowmeters, and pneumatic three-way sanitary divert valves. The system automatically routes fractions to separate spirit receivers based on predefined recipe criteria, while providing manual override options for distillers sensory evaluation.
Can fermentation cellar temperatures be controlled and monitored remotely?
Yes. Our fermentation control architecture regulates multi-zone glycol jacket solenoid valves for each conical fermenter and conditioning tank. Head brewers can monitor gravity attenuation, execute programmed diacetyl rest temperature ramps, and adjust cooling setpoints remotely via smartphone or tablet through a secure, encrypted SCADA interface with automated alarm notifications for temperature deviations.
Does your software assist with HMRC duty audit trails and compliance logging?
Yes. Our SCADA and batch logging architectures automatically record exact liquor volumes, grain bill weights, fermentation profiles, and spirit yield proofs. These records are stored in tamper-evident relational databases with automated reporting modules specifically formatted to simplify HMRC excise duty verification and traceability audits.
Bespoke Brewhouse & Distillery Engineering

Upgrade Your Brewhouse Efficiency, Cellar Control & Spirit Yield

Discuss your brewery expansion, new distillery installation, or brewhouse control panel upgrade with our senior EC&I engineers. We deliver bespoke electrical designs, ATEX/DSEAR compliance, and seamless on-site commissioning across the UK.

WhatsApp