Battery Energy Storage Systems (BESS): SCADA Integration, Container HVAC & G99 Grid Synchronisation

Engineered for UK renewable energy developers, EPC contractors, and DNO network operators. MASK Control Systems Ltd delivers turnkey utility-scale BESS master control panels, G99/G100 grid compliance, closed-loop container liquid cooling HVAC automation, NFPA 855 fire suppression interlocks, and multi-protocol DNP3/IEC 61850 substation SCADA gateways.

Battery Energy Storage System BESS SCADA and Control Panel Integration UK

Custom BESS master control panels engineered in Cullompton, Devon.

ENA G99
Certified Loss-of-Mains Protection
< 500ms
Dynamic Frequency Response (DFR)
NFPA 855
Automated Fire & Gas EPO Tripping
DNP3 / 61850
DNO & National Grid SCADA Telemetry

Ensuring Grid Stability & Thermal Safety for UK Energy Storage

The rapid rollout of utility-scale battery energy storage systems (BESS) across the UK is critical for stabilizing a grid saturated with intermittent wind and solar generation. However, connecting multi-megawatt lithium-ion storage assets to 11kV, 33kV, or 132kV distribution networks presents extreme engineering challenges: strict ENA Engineering Recommendation G99 disconnection compliance, real-time frequency response within 500 milliseconds, and catastrophic thermal runaway prevention under NFPA 855 directives.

Headquartered in Cullompton, Devon, MASK Control Systems Ltd delivers comprehensive automation and electrical engineering for stationary energy storage. We design and manufacture bespoke BESS master plant controllers, G99 protection switchboards, liquid cooling chiller automation panels, emergency power-off (EPO) safety loops, and cyber-secure DNP3 / IEC 61850 SCADA outstations for sites across the United Kingdom.

Technical Capabilities

Specialized Control & SCADA Engineering for Utility BESS Sites

From battery container thermal regulation to grid export limitation, our systems engineers deliver deterministic, sub-second automation:

ENA G99 & G100 Grid Protection Panels

Certified loss-of-mains protection relays continuously monitoring RoCoF (Rate of Change of Frequency), vector shift, and voltage stages. Integrates G100 fail-safe power transducers that throttle inverter export within 5 seconds to prevent grid overload.

Certified RoCoF & Export Limitation Tripping

Container Liquid Cooling & HVAC Loops

Precision thermal management for liquid-cooled cold plates and DX air handling units. Features modulating inverter-driven chiller compressors, glycol loop pump sequencing, and ambient economizer damper modulation maintaining cells between 20°C and 25°C.

Liquid Chiller Modulation & Thermal Uniformity

NFPA 855 Fire & Gas EPO Interlocks

Multi-stage safety architecture integrating early-warning off-gas sensors (H2, CO, VOCs), clean-agent Novec 1230 discharge monitors, explosion relief dampers, and fail-safe Emergency Power Off (EPO) signals tripping HV vacuum circuit breakers.

Off-Gas Early Warning & Circuit Breaker EPO

BMS Telemetry & Inverter Integration

Multi-protocol polling of battery management system (BMS) strings and power conversion system (PCS) inverters over Modbus TCP, CANopen, and Ethernet. Aggregates rack voltages, cell thermistors, state of charge (SOC), and state of health (SOH).

Sub-Second Multi-Inverter Coordination

DNP3 & IEC 61850 DNO SCADA Outstations

Secure RTU communications connecting the BESS plant directly to regional DNO control rooms (National Grid, UKPN, SSEN, SPEN). Supports DNP3 Outstation with secure authentication and IEC 60870-5-104 telemetry for real-time dispatch.

DNO Telemetry & Dynamic Frequency Response

Sub-Millisecond Fault Sequence Recording

GPS-synchronized IEEE 1588 PTP or IRIG-B time-stamping capturing sub-millisecond digital events during grid transient faults. Enables definitive post-mortem root-cause analysis for insurance and National Grid compliance sign-offs.

GPS Time-Stamped Sequence of Events (SER)
Grid & Fire Safety

Form 4b Switchboards, G99 Protection & Defra Environmental Safety

Utility-scale BESS sites combine high-voltage AC grid connections with high-current DC battery strings capable of delivering severe prospective short-circuit fault currents (exceeding 50kA).

MASK Control Systems designs auxiliary switchgear and control enclosures engineered for the harshest utility environments:

  • BS EN 61439-2 Form 4b Enclosures: Total physical compartmentalisation separating main copper busbars from outgoing feeder terminals, allowing safe maintenance without de-energizing adjacent battery strings.
  • Short-Circuit Withstand Validation: All switchboards, busbar droppers, and protection relays are calculated and sized to withstand peak prospective fault currents to BS EN 61439-1.
  • Dual-Redundant 110V DC UPS Battery Tripping: Fail-safe DC control power distribution ensuring that protection relays and motorized breaker trip coils remain active even during total AC blackout.

BESS Regulatory & Grid Code Matrix

ENA Engineering Recommendation G99UK Grid Code

Mandatory loss-of-mains RoCoF protection and frequency response for UK grid connections.

ENA Recommendation G100Export Limiting

Fail-safe power monitoring schemes preventing battery discharge from exceeding DNO export agreements.

NFPA 855 / IEC 62933Fire & Battery Safety

Stationary battery energy storage installation, thermal runaway containment, and gas detection standards.

IEC 61850 & DNP3 TelemetrySubstation SCADA

Standardized electrical substation communication protocols for automated remote dispatch.

Control Architecture

PLC Hardware, Cloud SCADA & Cyber-Secure Edge Gateways

We engineer scalable automation architectures built for the 20-year operational lifecycle of UK utility storage assets:

Siemens S7-1500 & SIPROTEC

Substation Tier

Redundant S7-1500R/H hot-standby CPUs paired with SIPROTEC numerical protection relays. Executes sub-500ms dynamic frequency response (DFR), active power ramps, and PROFINET communications to container I/O islands.

Rockwell ControlLogix 5580

Modular Gateway

High-throughput chassis architecture with dedicated ProSoft DNP3 and Modbus TCP communication co-processors. Interfaces with multiple battery inverter skids and auxiliary power distribution switchgear.

Ignition SCADA & Cloud

Real-Time Telemetry

Comprehensive HMI/SCADA platform delivering real-time single-line diagram (SLD) visualization, thermal heat maps across battery racks, revenue settlement logs, and automated alarm notification dispatch.

Technical Guidance

Frequently Asked Questions: BESS Automation

Key questions asked by UK renewable energy developers, EPC contractors, and DNO engineers:

How does MASK Control Systems ensure ENA Engineering Recommendation G99 compliance for BESS assets?
We engineer dedicated G99 protection panels housing certified multi-function loss-of-mains relays (such as ComAp InteliPro or Woodward). The system continuously monitors Rate of Change of Frequency (RoCoF), vector shift, over/under frequency (47.0Hz to 52.0Hz), and over/under voltage stages. In the event of grid detachment or islanding, the controller safely trips the master 33kV/11kV circuit breaker within statutory disconnection times (< 500ms) while providing fault ride-through (FRT) voltage support during transient dips.
What thermal management and HVAC controls are required for containerised battery storage?
Lithium iron phosphate (LFP) and NMC battery cells require tight thermal envelopes (typically 20°C to 25°C) to prevent thermal runaway and premature capacity loss. We engineer dual-redundant HVAC and liquid chiller control panels with modulating variable-speed scroll compressors, glycol loop circulation pumps, and motorized ambient economizer dampers. The PLC dynamically balances chilling load against real-time rack thermistor telemetry, maintaining cell temperature uniformity across multi-megawatt container suites.
How are fire suppression systems and emergency power-off (EPO) interlocked in BESS containers?
In accordance with NFPA 855 and UK fire authority guidelines, our control panels integrate multi-stage fire safety interlocks. Early-warning off-gas sensors (detecting hydrogen and carbon monoxide before thermal runaway) trigger local alarms and ventilation. If aerosol or clean-agent (Novec 1230 / FM-200) suppression discharges, the safety PLC initiates an immediate Emergency Power Off (EPO), tripping the DC contactors, opening the HV vacuum circuit breaker, and closing fire dampers to contain the extinguishant.
Which protocols are used to bridge battery management systems (BMS), inverters, and DNO SCADA?
We deploy industrial PLC gateways (Siemens S7-1500 or Rockwell ControlLogix) running multi-protocol translation. The controller polls lithium-ion BMS racks and bi-directional PCS inverters over Modbus TCP or CANbus, aggregates telemetry (cell voltages, SOC, SOH, alarms), and exposes DNP3 Outstation or IEC 61850 MMS data to the regional Distribution Network Operator (DNO) and National Grid ESO control rooms with encrypted telemetry.
Can MASK Control Systems implement G100 export and import limitation schemes?
Yes. ENA Engineering Recommendation G100 requires fail-safe export limitation when generation or storage capacity exceeds the agreed DNO grid connection capacity. We deploy fail-safe G100 compliant monitoring schemes utilizing dual-redundant class 0.5S power transducers and dedicated hardware watchdogs that automatically throttle inverter power output within 5 seconds if grid export thresholds are approached.
Utility Energy Storage Engineering

Engineer G99 Grid Compliance & SCADA Reliability for Your BESS

Discuss your utility-scale battery energy storage project, G99/G100 protection panel requirements, container liquid chiller automation, or DNO SCADA gateway with our senior control engineers. We deliver bespoke electrical designs, proven PLC software, and seamless on-site commissioning across the UK.